Search results for "Field test"

showing 10 items of 46 documents

Heart rate acceleration at relative workloads during treadmill and overground running for tracking exercise performance during functional overreaching

2020

AbstractMaximal rate of heart rate (HR) increase (rHRI) as a measure of HR acceleration during the transition from rest to exercise, or during an increase in workload, tracks exercise performance. rHRI assessed at relative rather than absolute workloads may track performance better, and a field test would increase applicability. This study therefore aimed to evaluate the sensitivity of rHRI assessed at individualised relative workloads during treadmill and overground running for tracking exercise performance. Treadmill running performance (5 km time trial; 5TTT) and rHRI were assessed in 11 male runners following 1 week of light training (LT), 2 weeks of heavy training (HT) and a 10-day tap…

0301 basic medicineAdultMalemedicine.medical_specialtysykekestävyysharjoittelulcsh:MedicineField testsWorkloadAthletic PerformanceArticleRunning03 medical and health sciences0302 clinical medicineTime trialTreadmill runningHeart RateInternal medicineylikuntoExercise performanceHeart rateMedicineHumansTreadmilllcsh:ScienceMultidisciplinaryExercise Tolerancebusiness.industrylcsh:Rautonomic nervous systemheart rate variabilitytype I syndactylyMiddle AgedOverreachingCardiovascular biologyharjoitusvasteCirculation030104 developmental biologyHeart rate accelerationCardiologyExercise Testlcsh:Qbusiness030217 neurology & neurosurgery
researchProduct

Influence of the luminance level on visual performance with a disposable soft cosmetic tinted contact lens.

2001

The purpose of the present work was to study the effect on visual performance of wearing disposable soft tinted contact lenses for cosmetic purposes. Parameters such as contrast sensitivity (Vistech 6000), colour vision (Farnsworth-Munsell 100-Hue colour test), visual fields (static Goldmann perimetry) and subjective vision (what the wearer feels while wearing the lenses) were studied under different illumination levels in order to check for possible vision losses while wearing these contact lenses at low illumination levels. Sixteen emmetropic subjects were fitted consecutively with seven pairs of different colour lenses (Optima Colors lenses by BauschLomb), and the experimental parameters…

AdultGoldmann perimetryAdolescentmedia_common.quotation_subjectColour VisionEmmetropiaColorContact Lenses HydrophilicLuminanceSensory SystemsContact lensContrast SensitivityOphthalmologyContrast (vision)OptometryHumansVisual Field TestsVisual FieldsColor PerceptionLightingVision OcularOptometryMathematicsmedia_commonOphthalmicphysiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
researchProduct

Adolescent physical fitness and activity as predictors of adulthood activity.

2011

A 25-year population-based study was conducted to determine how physical fitness and participation in leisure-time physical activity in adolescence (age 12-18 years) predict leisure-time physical activity in adulthood (age 37-43 years). In 1976, five field tests were conducted to measure muscular fitness, agility and aerobic capacity, and self-report weekly frequencies of activity were obtained by questionnaire. A modified questionnaire was repeated in 2001, when participants were age 37-43 years (N = 1525). On the basis of the questionnaire, a physical activity index was calculated both in 1976 and 2001. The odds ratios (OR) for being inactive in adulthood among those who were physically v…

AdultMaleAdolescentPopulationPhysical fitnessPhysical activityPhysical Therapy Sports Therapy and RehabilitationField testsDevelopmental psychologyLeisure ActivitiesSex FactorsSex factorsRisk FactorsSurveys and QuestionnairesOdds RatioHumansOrthopedics and Sports MedicineLongitudinal StudieseducationSelf reportChildExerciseSedentary lifestyleeducation.field_of_studybusiness.industryOdds ratioPhysical FitnessFemaleSelf ReportSedentary BehaviorPsychologybusinessDemographyJournal of sports sciences
researchProduct

Comparison of Dynamic Contour Tonometry and Goldmann Applanation Tonometry in Glaucoma Patients and Healthy Subjects

2006

To investigate the agreement in the measurement of intraocular pressure (IOP) obtained by dynamic contour tonometry PASCAL (DCT-PASCAL) and Goldmann applanation tonometry (GAT) in glaucoma eyes and healthy eyes with different central corneal thickness (CCT).Prospective cross-sectional study.In a randomized order, three consecutive IOP measurements were performed on 197 eyes of 107 subjects by one examiner using both DCT-PASCAL and GAT on all eyes. Furthermore, ultrasonic pachymetry was performed. The Spearman correlation coefficient (r) was determined to compare IOP readings between DCT-PASCAL and GAT. Regression-based Bland and Altman analysis was used to evaluate agreement between the ins…

AdultMaleApplanation tonometryIntraocular pressuremedicine.medical_specialtygenetic structuresEye diseaseVisual AcuityGlaucomaGoldmann applanation tonometryCorneaTonometry OcularOphthalmologyHumansMedicineProspective StudiesIntraocular PressureAgedUltrasonographyAged 80 and overbusiness.industryLimits of agreementHealthy subjectsReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional StudiesVisual Field TestsFemaleOcular Hypertensionsense organsbusinessAmerican Journal of Ophthalmology
researchProduct

Reliability in perimetric multichannel contrast sensitivity measurements

2014

Background: In this study, the reliability of perimetric contrast sensitivity measurements favouring the achromatic, the red-green and the blue-yellow post-receptorial mechanisms was analysed. Methods: A new technique, multichannel ATD perimetry, provides spatial and temporal stimuli favouring the detection by an achromatic mechanism (A), from a magno or parvocellular origin or by a red-green (RG) chromatic mechanism, with a parvocellular origin or a blue-yellow (BY) mechanism, with a koniocellular origin. The repeatability and reproducibility of contrast sensitivity measurements with these stimuli were studied in a group of 40 healthy subjects. The analysis was carried out on 21 testing po…

AdultMaleFovea Centralismedia_common.quotation_subjectMultichannel perimetryAgreementlaw.inventionContrast SensitivityYoung AdultOpticsParvocellular celllawHumansContrast (vision)RepeatabilityContrast sensitivityReliability (statistics)Ópticamedia_commonMathematicsReproducibilitybusiness.industryReproducibility of ResultsRepeatabilityHealthy VolunteersReproducibilityVisual fieldOphthalmologyKoniocellular cellROC CurveAchromatic lensVisual Field TestsFemaleVisual FieldsbusinessOptometryBiomedical engineeringClinical and Experimental Optometry
researchProduct

Image quality and visual performance in the peripheral visual field following photorefractive keratectomy.

2002

ABSTRACT PURPOSE: A theoretical and experimental study was performed to assess the possible effects of photorefractive keratectomy (PRK) on retinal image quality and thresholds in the peripheral visual field. METHODS: Simple optical calculations suggest that although the quality of the retinal image at the fovea of the postoperative PRK eye may be comparable to that in an emmetropic eye, images in the peripheral field may be markedly worse, since peripheral ray bundles may pass partly through ablated and partly through unablated cornea, giving a simultaneous-vision bifocal effect. This would be expected to create an annular zone of confusion, so that light from two different directions in o…

AdultMaleOptics and Photonicsgenetic structuresmedicine.medical_treatmentVisual AcuityEmmetropiaPhotorefractive Keratectomychemistry.chemical_compoundCorneaMyopiaHumansMedicineVision OcularRetinabusiness.industryRetinaleye diseasesPhotorefractive keratectomyVisual fieldOphthalmologymedicine.anatomical_structureMeridian (perimetry visual field)chemistrySensory ThresholdsVisual Field TestsOptometryFemaleLasers ExcimerSurgerysense organsVisual FieldsbusinessPhotopic vision
researchProduct

Structure-function relationship between FDF, FDT, SAP, and scanning laser ophthalmoscopy in glaucoma patients.

2012

Purpose Flicker defined form perimetry (FDF) and frequency doubling technology perimetry (FDT) are alleged to detect glaucoma at an earlier stage than standard automated perimetry (SAP). It is the purpose of this study to investigate the structure-function relationship between FDF, FDT, SAP, and confocal scanning laser ophthalmoscopy (cSLO) in patients with glaucoma. Methods Seventy-six patients with glaucoma were included in the study. Patients were tested with SAP, Matrix-FDT, FDF perimetry, and cSLO. Structure-function relationships between global and sectoral cSLO parameters and global and sectoral mean sensitivity (MS) of SAP, Matrix-FDT, and FDF were calculated using Spearman's rank c…

AdultMaleRetinal Ganglion CellsIntraocular pressuremedicine.medical_specialtygenetic structuresGlaucomaOphthalmologyLinear regressionmedicineHumansIn patientTomographyIntraocular PressureMathematicsRank correlationRetrospective StudiesAutomated perimetryStructure functionReproducibility of ResultsGlaucomaMiddle Agedmedicine.diseaseeye diseasesScanning laser ophthalmoscopyOphthalmoscopyVisual Field TestsFemaleVisual FieldsInvestigative ophthalmologyvisual science
researchProduct

Flicker Defined Form Perimetry in Glaucoma Suspects with Normal Achromatic Visual Fields

2014

To evaluate if repeated flicker-defined form (FDF) perimetry can detect visual field (VF) defects in glaucoma suspects with normal findings in achromatic standard automated perimetry (SAP).Patients with optic nerve heads (ONHs) or retinal nerve fiber layer (RNFL) findings clinically suspicious for glaucoma and normal SAP were enrolled. Patients underwent VF testing with FDF perimetry (Heidelberg Edge Perimetry, HEP) at two consecutive visits (HEP I and HEP II) and confocal scanning laser ophthalmoscopy with the Heidelberg Retina Tomograph (HRT). Abnormal HEP was defined by cluster-point analysis (CPA) and by the HEP specific glaucoma hemi-field test (GHT). Results were compared with an age-…

AdultMaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskVision DisordersVisual AcuityNerve fiber layerGlaucomalaw.inventionTonometry OcularCellular and Molecular Neurosciencechemistry.chemical_compoundNerve FiberslawOphthalmologymedicineHumansProspective StudiesIntraocular PressureHeidelberg retina tomographOptic Nerve Headsbusiness.industryGlaucomaRetinalMiddle Agedmedicine.diseaseeye diseasesSensory SystemsVisual fieldConfocal scanning laser ophthalmoscopyOphthalmologyEarly Diagnosismedicine.anatomical_structurechemistryAchromatic lensVisual Field TestsFemaleOcular Hypertensionsense organsVisual FieldsbusinessCurrent Eye Research
researchProduct

Comparison of cyclodeviation and duction measurement in Graves' orbitopathy patients using different devices

2011

To compare measurement outcomes of different devices measuring cyclodeviation and ductions in Graves' orbitopathy (GO) patients. Cyclodeviation in GO patients was measured using the Harms tangent screen (HTS), the cycloforometer of Franceschetti, and the synoptometer. Ductions were measured using the modified perimeter, the Goldmann perimeter and the Maddox tangent scale (MTS). In 13 patients, cyclodeviation in primary position, up-, and downgaze was measured with the above-mentioned devices. The mean differences ranged from 0.3º to 3.1º and were smallest between the HTS and the cycloforometer (89% of all measurements within 2º difference). Measurement of abduction, adduction, elevation, an…

AdultMalemedicine.medical_specialtyEye Movementsbusiness.industryEquipment DesignPrimary positionDiagnostic Techniques OphthalmologicalMiddle AgedTangent screenGraves DiseasePerimeterOphthalmologyOphthalmologymedicineHumansVisual Field TestsGoldmann perimeterFemalebusinessAgedStrabismus
researchProduct

Type A Behavior Pattern

2012

Aim : To evaluate the presence of type A behavior in patients affected by open-angle glaucoma (OAG) and the possible role of psychophysiological stress as a risk factor for OAG. Materials and methods Fifty patients, 30 women and 20 men, affected by OAG, underwent ophthalmological examination consisting of complete biomicroscopy, tonometry and daily tonometric curve, examination of the visual field by means of computerized perimeter "Octopus 1-2-3," and its assessment with the Glaucoma Staging System 2, morphologic monitoring of the retinal nerve fiber layer with GDx VCC and psychological assessment (Hamilton Anxiety Rating Scale) to evaluate the presence of anxiety and its level; type A/B p…

AdultMalemedicine.medical_specialtyIntraocular pressureOpen angle glaucomaHamilton Anxiety Rating ScaleType A Behavior Patternmedia_common.quotation_subjectGlaucomaManifest Anxiety ScaleTonometry OcularRisk FactorsOphthalmologyHumansMedicinePersonalityPsychological testingIntraocular PressureAgedmedia_commonSettore MED/30 - Malattie Apparato Visivobusiness.industryType A PersonalityType A and Type B personality theoryMiddle Agedmedicine.diseaseOpen-Angle Chronic GlaucomaOphthalmologyquality of lifeChronic DiseaseVisual Field TestsAnxietyFemaleVisual Fieldsmedicine.symptombusinessGlaucoma Open-AngleStress PsychologicalJournal of Glaucoma
researchProduct